{"id":1016,"date":"2014-07-10T17:36:46","date_gmt":"2014-07-10T15:36:46","guid":{"rendered":"https:\/\/ht-eurep.de\/produkte\/vi-tester\/fados9f1\/"},"modified":"2025-05-30T09:33:30","modified_gmt":"2025-05-30T07:33:30","slug":"fados9f1","status":"publish","type":"page","link":"https:\/\/ht-eurep.de\/en\/products\/vi-tester\/fados9f1\/","title":{"rendered":"FADOS9F1"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column width=&#8221;1\/1&#8243;][vc_column_text css_animation=&#8221;appear&#8221;]<div class=\"gap\" style=\"line-height: 1px; height: 1px;\"><\/div>\n<p style=\"text-align: center;\"><a class=\"dt-pswp-item\" href=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/FADOS9F1.jpg\" data-dt-img-description=\"\" data-large_image_width=\"774\" data-large_image_height=\"602\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-3687\" src=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/FADOS9F1-300x233.jpg\" alt=\"\" width=\"300\" height=\"233\" srcset=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/FADOS9F1-300x233.jpg 300w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/FADOS9F1-768x597.jpg 768w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/FADOS9F1.jpg 774w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2014\/09\/FADOS9F1-English-Datasheet-long.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Download Datasheet<\/a><\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.youtube.com\/playlist?list=PL7aapOs5HevIxYVHUvq2cbt4WY8JcM1sK\" target=\"_blank\" rel=\"noopener\">Videos<\/a><\/p>\n<div class=\"gap\" style=\"line-height: 1px; height: 1px;\"><\/div>[\/vc_column_text][vc_column_text css_animation=&#8221;right-to-left&#8221; css=&#8221;.vc_custom_1499334380553{padding: 20px !important;background-color: #ffffff !important;border-color: #ffffff !important;border-style: solid !important;}&#8221;]<\/p>\n<p style=\"text-align: justify;\"><span style=\"color: #333333;\">The system is developed by ProT Ar-Ge Industrial Project Design R &amp; D Ltd. Co. as a V\/I tester with PC oscilloscope function to troubleshoot printed circuit boards. FADOS9F1 is, compared to FADOS7F1, equipped with two additional functions, which currently no other system on the market can offer. The system offers the following 9 functions in one device.<\/span><\/p>\n<h4><span style=\"color: #333333;\">Features<\/span><\/h4>\n<ul>\n<li><span style=\"color: #333333;\"><strong>Two Channel error detection by V \/ I tester (analog signature analysator):<\/strong> Fault detection by direct comparison of the current-voltage characteristics (signatures) of a working and a faulty circuit board without applying power to the unit under test.<\/span><\/li>\n<li><span style=\"color: #333333;\"><strong>Fault detection by comparison with stored signatures:<\/strong> Signatures of a functioning board can be saved and used at a later time as a reference for troubleshooting a faulty board. The point to touch can be indicated by a cross hair mark at an image of the board.<\/span><\/li>\n<li><span style=\"color: #333333;\"><strong>Equivalent circuit diagram:<\/strong> Display of an equivalent circuit that corresponds to the characteristic on the touched point.***<\/span><\/li>\n<li><span style=\"color: #333333;\"><strong>Display values of resistor, capacitor and diode threshold:<\/strong> Display the calculated values of resistance, capacitors and diode threshold voltages corresponding to the conditions at the contacted node.***<\/span><\/li>\n<li><span style=\"color: #333333;\"><strong>Dual-channel digital PC oscilloscope<\/strong><\/span><\/li>\n<li><span style=\"color: #333333;\"><strong>0.2&#8230; 25KHz square wave output:<\/strong> Channel 2 is used as a square wave generator. Channel 1 can be used as an oscilloscope.<\/span><\/li>\n<li><span style=\"color: #333333;\"><strong>Analog voltage output:<\/strong> Analog DC output +4.8 V -4.7 V 2 &#8230; (100 mV steps) on channel Channel 1 can be used as an oscilloscope.<\/span><\/li>\n<li><span style=\"color: #333333;\"><strong>Programmable integrated DC power supply:<\/strong> The output voltage is adjustable. 0 to 16 volts with an output current 20 to 1500 mA.***\u00a0<\/span><\/li>\n<li><span style=\"color: #333333;\"><strong>Non touched IR temperature probe:<\/strong> To detect more heated components and draw a heat map of the UUT.<\/span><\/li>\n<\/ul>\n<p><span style=\"color: #333333;\">*** These functions in combination are currently only offered by FADOS products!<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"color: #333333;\">For the following European countries you can also directly get in touch with our <span style=\"text-decoration: underline;\">local partners<\/span>:<br \/>\nFrance: Deltest, Ghislain Hazard, hazard@deltest.com<br \/>\n<span style=\"color: #333333;\">Italy: NUATECH, Fabrizio Tatti, info@nuatech.it<\/span><\/span><span style=\"color: #333333;\"><br \/>\n<\/span>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/1&#8243;]<div class=\"gap\" style=\"line-height: 30px; height: 30px;\"><\/div><div class=\"hr-thin style-line\" style=\"width: 100%;border-color: #cecece;border-top-width: 1px;\"><\/div><div class=\"gap\" style=\"line-height: 10px; height: 10px;\"><\/div>[vc_toggle title=&#8221;further information&#8221; open=&#8221;false&#8221;]<span style=\"color: #333333;\"><strong>Applications:<br \/>\n<\/strong>All companies or departments with the task of troubleshooting and repair of populated electronic boards will be very quickly convinced of the benefits of the system in their daily work. It makes no difference whether the test objects coming from the automotive sector, medical, motor control, video, audio, mobile phone or any other areas in which electronic components are used.<\/span><\/p>\n<p><span style=\"color: #333333;\">While troubleshooting, the FADOS9F1 is a very useful and reliable tool.<\/span><br \/>\n<span style=\"color: #333333;\">The benefit of the test method is the fact troubleshooting is done without applying power to the UUT and there is no risk for consequential damages due to any existing shorts, defective components or low-impedance connections on the faulty board.<\/span><br \/>\n<span style=\"color: #333333;\">The FADOS9F1 offers in comparison to the FADOS7F1 additionally a programmable power supply and a non-contact IR temperature measurement. This programmable power supply can be used to connect to the powerlines of the UUT and a maximum voltage value is set. Now the power \u201ctest button\u201d can be activated and the software generates a output by 100 mV steps up to the set maximum value. The values of voltage and current are saved in a file. After a short time the IR temperature measurement can be done and a component with a defect-related, higher temperature can be determined. The software screen can also integrate the microscope picture from a USB camera, which is especially handy if working with very small components.<br \/>\n<\/span><\/p>\n<p><span style=\"color: #333333;\"><strong>Special features:<br \/>\n<\/strong>The representation of an equivalent circuit of an intelligent analysis of the current-voltage curve is a unique feature. No other product can come up with something similar in this area. You can see below the curve(s), a simplified circuit with the resistance and capacitance values of the contacted node (see screenshot below).<\/span><\/p>\n<p><span style=\"color: #333333;\"><strong>FADOS9F1 delivery:<\/strong><\/span><\/p>\n<ul>\n<li><span style=\"color: #333333;\">FADOS9F1 product<\/span><\/li>\n<li><span style=\"color: #333333;\">2 probe tips (oscilloscope probes)<\/span><\/li>\n<li><span style=\"color: #333333;\">USB cable<\/span><\/li>\n<li><span style=\"color: #333333;\">IR temperature sensor<\/span><\/li>\n<li><span style=\"color: #333333;\">Power cable red \/ black with alligator clips<\/span><\/li>\n<li><span style=\"color: #333333;\">Power Adapter (19V, 3.9A)<\/span><\/li>\n<li><span style=\"color: #333333;\">CD with software and user manual FADOS9F1 program<\/span><\/li>\n<li><span style=\"color: #333333;\">FADOS9F1 box<\/span><\/li>\n<\/ul>\n<p>[\/vc_toggle]<div class=\"gap\" style=\"line-height: 20px; height: 20px;\"><\/div><div class=\"hr-thin style-line\" style=\"width: 100%;border-color: #cecece;border-top-width: 1px;\"><\/div>[\/vc_column][\/vc_row][vc_row][vc_column width=&#8221;1\/1&#8243;]<div class=\"gap\" style=\"line-height: 10px; height: 10px;\"><\/div>[vc_toggle title=&#8221;further pictures&#8221; open=&#8221;false&#8221;]<span style=\"color: #333333;\">Equivalent circuit:<\/span><\/p>\n<p><a href=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2014\/07\/FADOS-Schaltung_1.jpg\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-678\" src=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2014\/07\/FADOS-Schaltung_1-300x82.jpg\" alt=\"FADOS-Schaltung_1\" width=\"300\" height=\"82\" srcset=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2014\/07\/FADOS-Schaltung_1-300x82.jpg 300w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2014\/07\/FADOS-Schaltung_1.jpg 416w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Dual channel VI graph und equivalent circuit diagram:<\/p>\n<p><a class=\"dt-pswp-item\" href=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/1.jpg\" data-dt-img-description=\"\" data-large_image_width=\"1024\" data-large_image_height=\"765\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-3671\" src=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/1-300x224.jpg\" alt=\"\" width=\"300\" height=\"224\" srcset=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/1-300x224.jpg 300w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/1-768x574.jpg 768w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/1.jpg 1024w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Comparison feature: Channel 1 (red) good card signal, Channel 2 (blue) defective board:<\/p>\n<p><a class=\"dt-pswp-item\" href=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/2.jpg\" data-dt-img-description=\"\" data-large_image_width=\"1014\" data-large_image_height=\"732\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-3673\" src=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/2-300x217.jpg\" alt=\"\" width=\"300\" height=\"217\" srcset=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/2-300x217.jpg 300w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/2-768x554.jpg 768w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/2.jpg 1014w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Memory recording feature. Good VI graph recorded with CH (red) 1 probe. Comparison from defective PCB with CH 2 (blue) probe. Picture shows contacted test point on PCB:<\/p>\n<p><a class=\"dt-pswp-item\" href=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/3.jpg\" data-dt-img-description=\"\" data-large_image_width=\"1009\" data-large_image_height=\"729\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-3675\" src=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/3-300x217.jpg\" alt=\"\" width=\"300\" height=\"217\" srcset=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/3-300x217.jpg 300w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/3-768x555.jpg 768w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/3.jpg 1009w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>The faulty component on bad PCB can be quickly detected by major difference:<\/p>\n<p><a class=\"dt-pswp-item\" href=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/4.jpg\" data-dt-img-description=\"\" data-large_image_width=\"1014\" data-large_image_height=\"730\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-3677\" src=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/4-300x216.jpg\" alt=\"\" width=\"300\" height=\"216\" srcset=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/4-300x216.jpg 300w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/4-768x553.jpg 768w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/4.jpg 1014w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>By using both channels, it is checked whether the (unsoldered) semiconductor parts (transistor, thyristor, FET, IGBT) are contacting and whether they leak:<\/p>\n<p><a class=\"dt-pswp-item\" href=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/5.jpg\" data-dt-img-description=\"\" data-large_image_width=\"1014\" data-large_image_height=\"729\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-3679\" src=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/5-300x216.jpg\" alt=\"\" width=\"300\" height=\"216\" srcset=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/5-300x216.jpg 300w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/5-768x552.jpg 768w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/5.jpg 1014w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p>Power IR test: In this technique, power cable is connected the input of solid card and set maximum voltage. Click \u201cPower Test\u201d button; software creates 100 mV steps DC voltage-current graph from 0 to Vmax. and saves a file.<br \/>\nAfter waiting a few minutes, it will be easy to detect more heated components and draw out heat map of electronic card:<\/p>\n<p><a class=\"dt-pswp-item\" href=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/6.jpg\" data-dt-img-description=\"\" data-large_image_width=\"668\" data-large_image_height=\"483\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-3681\" src=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/6-300x217.jpg\" alt=\"\" width=\"300\" height=\"217\" srcset=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/6-300x217.jpg 300w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/6.jpg 668w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a><\/p>\n<p><span style=\"color: #333333;\">Oscilloscope feature: This section is a low frequency oscilloscope offered as an additional feature. It can be used as a square wave signal or an analog voltage source from channel 2. Its sensitivity is 6mV.<br \/>\n<\/span><\/p>\n<p><a class=\"dt-pswp-item\" href=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/7.jpg\" data-dt-img-description=\"\" data-large_image_width=\"1031\" data-large_image_height=\"764\"><img decoding=\"async\" loading=\"lazy\" class=\"alignnone size-medium wp-image-3683\" src=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/7-300x222.jpg\" alt=\"\" width=\"300\" height=\"222\" srcset=\"https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/7-300x222.jpg 300w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/7-1024x759.jpg 1024w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/7-768x569.jpg 768w, https:\/\/ht-eurep.de\/wp-content\/uploads\/2025\/02\/7.jpg 1031w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/a>[\/vc_toggle]<div class=\"gap\" style=\"line-height: 20px; height: 20px;\"><\/div><div class=\"hr-thin style-line\" style=\"width: 100%;border-color: #cecece;border-top-width: 1px;\"><\/div>[\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column width=&#8221;1\/1&#8243;][vc_column_text css_animation=&#8221;appear&#8221;] Download Datasheet Videos [\/vc_column_text][vc_column_text css_animation=&#8221;right-to-left&#8221; css=&#8221;.vc_custom_1499334380553{padding: 20px !important;background-color: #ffffff !important;border-color: #ffffff !important;border-style: solid !important;}&#8221;] The system is developed by ProT Ar-Ge Industrial Project Design R &amp; D Ltd. Co. as a V\/I tester with PC oscilloscope function to troubleshoot printed circuit boards. FADOS9F1 is, compared to FADOS7F1, equipped with two additional functions,&hellip;<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":1010,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/ht-eurep.de\/en\/wp-json\/wp\/v2\/pages\/1016"}],"collection":[{"href":"https:\/\/ht-eurep.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ht-eurep.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ht-eurep.de\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/ht-eurep.de\/en\/wp-json\/wp\/v2\/comments?post=1016"}],"version-history":[{"count":19,"href":"https:\/\/ht-eurep.de\/en\/wp-json\/wp\/v2\/pages\/1016\/revisions"}],"predecessor-version":[{"id":3709,"href":"https:\/\/ht-eurep.de\/en\/wp-json\/wp\/v2\/pages\/1016\/revisions\/3709"}],"up":[{"embeddable":true,"href":"https:\/\/ht-eurep.de\/en\/wp-json\/wp\/v2\/pages\/1010"}],"wp:attachment":[{"href":"https:\/\/ht-eurep.de\/en\/wp-json\/wp\/v2\/media?parent=1016"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}